Nivisys, LLC Rev. 14 Aug 2014
3-5
Figure 3-3 Battery Power Icons
Two conditions determine the length of time the unit will
operate on a set of batteries:
1. The brightness setting on the display.
2. The temperature at which the unit operates.
NOTE
WHEN THE FLASHING LOW BATTERY
INDICATOR APPEARS, THE UNIT HAS
APPROXIMATELY 5 MINUTES OF BATTERY
LIFE BEFORE AUTOMATIC SHUTDOWN.
3.6 Thermal Calibration:
The UTAM Series features shutterless core technology and the
lens cover unit must be closed when calibrating the system.
Calibration gives the user the clearest picture possible. To
calibrate the system perform the following procedure.
1. Fully close the lens cover.
2. Simultaneously press the front and center buttons.
The UTAM Series will automatically perform an initial
calibration at power up. For this reason it is necessary to keep
the lens cover closed for a minimum of 2 seconds at power up.
BATTERY
CHARGE
FULL
BATTERY
CHARGE
EMPTY